SALE!
Request our catalog number 10
Aquamerik.com in
your favorites!
Free flashlight!
Big deal

> Catalogue
Accessories
Aerator systems
Alarms
Water analysis
Environmental analysis
Aquariums & accessories
Scale & counters
Tanks
Biofiltration
Heaters & water chillers
Chemicals
Air pumps
Flowmeters
Diffusers
Lab equipment
Filtration
Fountains and water gardens
Gloves
Hatchery equipment
Timers
Feeders
Feeds
Oxygenation
Plumbing
Pumps (Water)
Predator control
Nets & netting
Greenhouse
Regenerative blowers
Monitoring systems
Thermometers
Fish Transportation
Pipes
Valves

Eggs and fish

> Environment

Shopping Cart
Home   About Us   Documentation   Ressources   Contact Us

By Keywords
Go To the Home Page
 Heaters & water chillers >
Chiller and heat pumps
  > Printable version
Aquamerik is a pioneer in the distribution of efficient titanium chillers and heat pumps to provide environmental water temperature control for the aquatic market. After hundreds of installations around the world, we are flattered that this technology has become the accepted inàustry standard. While others attempt to copy our designs, we are secure in our reputation as the undisputed leader, based on an ongoing commitment to quality, dependability and innovation. Every part that comes into contact with water is completely inert and
non-corrosive, eliminating environmental contamination. In addition, the heat exchange shell, coil and temperature probe use pure titanium for high heat exchange rate and maximum efficiency.

 

When you specify a Aquamerik chiller or heat pump, combined with our electronic temperature controller, you enjoy the confidence of having the safest, most reliable and failure-free system ever manufactured. Each is designed to be installed in line with a recirculating spstem.
 
Automatic heating-chilling units up to 1 hp incorporate a titanium exchange coil plus a separate titanium heater. The heating element can be removed without disconnecting from the water supply or risking any contamination.
 
Units greater than 1 hp feature reversible cycle heat pumps with titanium exchange coils. Heat pumps are as much as 3 times more efficient than electric heaters. AII UMI heat pumps feature an adjustable overheating protection device for failsafe opration, plus indicator lights for defrost, high head pressure and overheating protection.

 

  UTCH Chiller/Heater Specifications 1,3
Model #
Nominal HP
Cooling Amps @ VAC, 1Ø
Heating (2) Amps @ VAC, 1Ø
Water Connections
Nominal Flow Rate
US GPM 4
115
208-230
115 208-230
UTCH-0
1/5
3.9
4.5
  1" FNPT
5-40
UTCH-1
1/4
4.9
4.5
  1" FNPT
10-40
UTCH-2
1/3
7.3
4.5
  1" FNPT
10-40
UTCH-3
1/2
9.3
4.5
  1" FNPT
10-40
UTCH-4
3/4
15.0
7.1
9.0
4.5 1" FNPT
10-40
UTCH-5 1   7.3   4.5 1" FNPT (5) 10-40
UTCH-6
1 1/2
9.3
4.5 2" SPG
20-100
  1. Specifications subject to change without notice. Dimensions similar to Ti-CHAM series chillers.
2. Electric bayonet style heaters mounted in heat exchangers.
3. Electric heating units provided with high temperature cut-out switch.
4. Flow rate requirements are relative to water temperature. As a rule, colder water requires higher flow.
5. Available with 1 1/2" SPG water connections.
 


  UTCH Heat Pump Specifications @ 208-230 VAC, 1Ø 1
Model #
Nominal HP
Amps
Water Connections
Nominal Flow Rate
US GPM 2
UTCH-7
2
11.7
2" SPG
20-100
UTCH-8
3
17.2
2" SPG
20-100
UTCH-9
5
30.4 2" SPG
50-100
  1. Specifications subject to change without notice.
2. Flow rate requirements are relative to water temperature. As a rule, colder water requires higher flow.
 

 

  UTCH Heat Pump Specifications @ 3Ø 1
Model #
Nominal HP
Amps @ Voltage
Water Connections
Nominal Flow Rate
US GPM 2
208-230
460 575
UTCH-8
3
13
7   2" SPG
20-100
UTCH-9
5
20.5
10   2" SPG
20-100
UTCH-10
7 1/2
32
15
12 2" SPG
50-100
UTCH-11
10
44
21
13 2" SPG
50-100
UTCH-12
15
65
30
24 2" SPG
50-100
  1. Specifications subject to change without notice.
2. Flow rate requirements are relative to water temperature. As a rule, colder water requires higher flow.

 

UTC Chiller Specifications 1
Model #
Nominal HP
Amps @ VAC, 1Ø
Nominal Flow Rate
US GPM 2
Dimensions 3
L" x W" x H"
115
208-230
UTC-0
1/5
3.9
5-40
20" x 16" x 12"
UTC-1
1/4
4.9
10-40
20" x 16" x 12"
UTC-2
1/3
7.3
10-40
20" x 16" x 12"
UTC-3
1/2
9.3
10-40
20" x 20" x 13"
UTC-4
3/4
15.0
7.1
10-40
24" x 26" x 16"
UTC-5
1
7.3
10-40
26" x 26" x 16"
  1. Specifications subject to change without notice.
2. Flow rate requirements are relative to water temperature. As a rule, colder water requires higher flow.
3. Dimensions may vary, if size is critical please contact UMI to discuss options.
 

 

  UTC Commercial Chiller Specifications 1
Model #
Nominal HP
Amps @ 208-230 VAC
Nominal Flow Rate
US GPM 2
UTC-6
1 1/2
10.8
20-100
UTC-7
2
13.4
20-100
UTC-8
3
22.5
14.3
20-100
UTC-9
4
30.1
21.4
20-100
UTC-10
5
34.3
21.4
50-100
  1. Specifications subject to change without notice. Dimensions available on request.
2. Flow rate requirements are relative to water temperature. As a rule, colder water requires higher flow.



 Additionnal information:

  > COOLING UNIT SELECTION CHART

ITEM
DESCRIPTION
CAD PRICE
EASY ORDER
 CHILLERS
UTC-0
Chiller 1/5 HP, 115 volts, Titanium coil.
1,398.00 $
UTC-1
Chiller 1/4 HP, 115 volts, Titanium coil.
1,615.00 $
UTC-2
Chiller 1/3 HP, 115 volts, Titanium coil.
1,754.00 $
UTC-3
Chiller 1/2 HP, 115 volts, Titanium coil.
2,119.00 $
UTC-4
Chiller 3/4 HP, 115 volts, Titanium coil.
2,805.00 $
UTC-5
Chiller 1 HP, 115 volts, Titanium coil.
3,066.00 $
 CHILLER AND HEATER
UTCH-0
Chiller / Heater 1/5 HP, 115 volts, Titanium coil.
1,725.00 $
UTCH-1
Chiller / Heater 1/4 HP, 115 volts, Titanium coil.
1,955.00 $
UTCH-2
Chiller / Heater 1/3 HP, 115 volts, Titanium coil.
2,156.00 $
UTCH-3
Chiller / Heater 1/2 HP, 115 volts, Titanium coil.
2,535.00 $
UTCH-4
Chiller / Heater 3/4 HP, 115 volts, Titanium coil.
3,260.00 $
UTCH-5
Chiller / Heater 1 HP, 208 / 230 volts, Titanium coil.
3,536.00 $
UTCH-6
Chiller / Heater 1.5 HP, 208 / 230 volts, Titanium coil.
5,159.00 $
UTCH-7
Chiller / Heater 2 HP, 208 / 230 volts, Titanium coil.
6,779.00 $
UTCH-8
Chiller / Heater 3 HP, 208 / 230 volts, Titanium coil.
8,340.00 $
UTCH-9
Chiller / Heater 5 HP, 208 / 230 volts, Titanium coil.
10,614.00 $
UTCH-10
Chiller / Heater 7.5 HP, 208 / 230 volts, Titanium coil.
14,377.00 $
UTCH-11
Chiller / Heater 10 HP, 208 / 230 volts, Titanium coil.
19,223.00 $
UTCH-12
Chiller / Heater 15 HP, 208 / 230 volts, Titanium coil.
29,894.00 $
UTCH-13
Chiller / Heater 20 HP, 208 / 230 volts, Titanium coil.
36,848.00 $
Last Update: May 10, 2006
Prices are in canadian dollars and can change without notice.

 > Back to Heaters & water chillers
16030

Purchase Order
Step 1/3
Item ID
Description
Price
Quantity
Total
Your order is empty, please add a product in your order.


Partial total
.00$


788, Blv. Methot, St-Nicolas (QC) CANADA - G7A 3W4 - Toll Free : (888) 278-4776 - Fax : (418) 831-2882